Briza 22 2-pipe
Super-power for heating, cooling and ventilation
- A climate unit with a dual personality
- Provides comfortable heat in winter and refreshing cooling in summer
- Provides you with an optimum indoor climate throughout the year
- Ideal for connecting to low-temperature systems like heat pumps,
solar energy systems and condensing boilers


Composition
Outputs
Options
Connection sets
Pre-mounted Jaga Fancoil controller (JFCC)
Jaga Fan Coil Controller increases the functionalities of the Jaga products. The JFCC is available for all Jaga Briza 22 devices. The controller is delivered pre-set and mounted in the unit. The device is controlled by the home automation system or BMS.
Control via BMS or external thermostat
- Control per appliance, without control panel
- With water temperature sensor
- Power supply 230 VAC
- With key card contact / window contact
- Heating / cooling
- Heating: configured at water temperature >28°C, can easily be modified
- Cooling: configured at water temperature <18°C, can easily be modified
- 0-10 V input for building management system/thermostats
Code |
|
FCC.BR712 |
Heating 2-pipe |
FCC.BR722 |
Heating / Cooling 2-pipe |
FCC.BR724 |
Heating / Cooling 4-pipe |
Control with 3-position control panel
- Control with a pushbutton control and a water and room temperature sensor(s)
- Heating/cooling with automatic switch
- Power supply 230 VAC
- With key card contact / window contact
- Heating: configured at water temperature >28°C, can easily be modified
- Cooling: configured at water temperature <18°C, can easily be modified
Code |
|
FCC.BRC42 |
Heating 2-pipe |
FCC.BRC62 |
Heating / Cooling 2-pipe |
FCC.BRC64 |
Heating / Cooling 4-pipe |
Clock thermostats heating / cooling
for recessed mounting
New: Jaga clock thermostat for recessed/panel mounting - JRT-100TW
- LCD touchscreen with background lighting
- control via WIFI (smartphone app)
- programmable time zones 7 days (1-7)
- Control valves 24 VDC heating/cooling
- Thermostat to be mounted in a junction box
- Spacing holes at 6 cm
- Minimum depth 4.5 cm
- Iinner dimension 5 x 5 cm or Ø 6 cm
Code |
|
8751.050017 |
Built-in |
Jaga clock thermostat for recessed/panel mounting - JRT-100
- Control valves 24 VDC heating/cooling
- Thermostat to be mounted in a junction box
- Spacing holes at 6 cm
- Minimum depth 4.5 cm
- Iinner dimension 5 x 5 cm or Ø 6 cm
Code |
|
8751.050012 |
Built-in |
for wall mounting
Jaga clock thermostat for wall mounting - JRT-200
- 2 potential-free contacts heating/cooling (f.e. valve contol 24 VDC or 230 VAC)
- With key card contact / window contact
- Can be mounted on a junction box with screw holes at 6 cm
Code
|
|
8751.050013 |
Wall mounted |
Siemens clock thermostat for wall mounting - RDG-160T
- Unlimited adjustment possibilities: 74 features and diagnostic test
Code |
|
8751.050009 |
Wall mounted |
Filter
- Filter Class G2
- Fire-safe according to DIN 53438 (F1)
Code |
Length Briza |
8721.401 |
55 |
8721.402 |
75 |
8721.403 |
95 |
8721.404 |
125 |
8721.405 |
155 |
Corner piece 90°
Inbouwmaten
Air inlet corner piece 90°
- Suitable for Briza 22 BT & FT
- Height control -1 to + 4 cm
- Galvanised steel plate
Code | L Briza |
8787.0101 |
55 |
8787.0102 |
75 |
8787.0103 |
95 |
8787.0104 |
125 |
8787.0105 |
155 |
Air outlet corner piece 90°
- Suitable for Briza 22 BT & BF
- Height control -1 to + 4 cm
- Galvanised steel plate
Code | L Briza |
8788.0101 |
55 |
8788.0102 |
75 |
8788.0103 |
95 |
8788.0104 |
125 |
8788.0105 |
155 |
Grille for corner piece 90°
Code |
L Briza |
Building in-opening |
8789.201 |
55 |
50 x 15 |
8789.202 |
75 |
70 x 15 |
8789.203 |
95 |
90 x 15 |
8789.204 |
125 |
120 x 15 |
8789.205 |
155 |
155 x 15 |
Plenum 180°
Air inlet corner piece 90°
- Connection ø 20 cm
- To fit on the air inlet side
- Galvanised steel plate
Code |
L Briza |
# Connections |
8764.0501 |
55 |
2 |
8787.0502 |
75 |
2 |
8787.0503 |
95 |
3 |
8787.0504 |
125 |
4 |
8787.0505 |
155 |
5 |
Air outlet corner piece 90°
- Connection ø 20 cm
- Acoustically and thermally insulated internal surfaces
- To fit on the air exhaust side
- Galvanised steel plate
Code |
L Briza |
# Connections |
8764.0601 |
55 |
2 |
8787.0602 |
75 |
2 |
8787.0603 |
95 |
3 |
8787.0604 |
125 |
4 |
8787.0605 |
155 |
5 |
Manual
Mounting instructions JDPC.003
Mounting instructions JFCC
Mounting instructions Maximum cable length