Briza 12


Ultra-slender, super-powerful for heating, cooling, ventilation

  


  • A climate unit with a dual personality
  • Provides comfortable heat in winter and refreshing cooling in summer
  • Provides you with an optimum indoor climate throughout the year
  • Ideal for connecting to low-temperature systems like heat pumps, solar energy systems and condensing boilers

TopPerformers HybridHeating

Images

Price list

 

Dimensions

Jaga Briza Afmeting 

Outputs & Availability

HEATINGCOOLING
TOTAL
COOLING
SENSIBLE
-
Height

[cm]
Length

[cm]
Width

[cm]
Speed

[V]
75/65/20

[Watts]
55/45/20

[Watts]
45/40/20

[Watts]
35/30/20

[Watts]
7/12/25
50% R.H.
[Watts]
7/12/25
50% R.H.
[Watts]
Ordering codeAvailability

[Day(s)]
AllAllAllAll
Loading data from server ...

 

Technical data

Height

[cm]
Length

[cm]
Width

[cm]
Speed

[V]
Sound pressure
according to ISO 3741:2010
[dB(A)]
Rated
input
[Watts]
Air flow
with clean filters
[m3/h]
Water flow
75/65/20
[litre/h]
Water flow
7/12/25
[litre/h]
AllAllAllAll
Loading data from server ...

 

 

Recommended combinations

  Heating and / or cooling Heating
  Including thermostat Including built-in thermostat Without thermostat Without thermostat Radiator version with thermostatic head
Regulation Thermostat heating/cooling
Ordering code 8751.050009
Built-in and pre-wired thermostat
Add ordering code /T to ordering code
Pre-mounted JDPC with control panel
Ordering code DPC.BRC6
Pre-mounted JDPC with control panel
Ordering code DPC.BRC4
Thermostatic head option
Add ordering code /RAD to ordering code
Power supply Pre-mounted power supply
Add ordering code /P to ordering code
Pre-mounted power supply Pre-mounted power supply
Add ordering code /P to ordering code
Pre-mounted power supply
Add ordering code /P to ordering code
Pre-mounted power supply
Connection set Connection set 95 with motor 24 VDC 0-10V

Ordering code CODY.SC5.10.3...

... Fill in sleeve coupling codes M24
(Included in the price)
Pre-mounted connection set

Order sleeve couplings M24 seperate

See "Built-in thermostat"
Connection set 90 with
2 lockshields

Ordering code CODY.LOC.00.3...

... Fill in sleeve coupling codes M24
(Included in the price)
Connection set 90 with
2 lockshields

Ordering code CODY.LOC.00.3...

... Fill in sleeve coupling codes M24
(Included in the price)
Pre-mounted connection set

Order sleeve couplings M24 seperate

See "Built-in thermostat"

Options


Connection sets

  • Alle
  • 2pipe
  • M24
  • Wall
  • Standard
  • Titel
  • Datum
  • Zufall

Sleeve couplings M24

Precision metal tube
Code Description
5094.110 ∅ M24 x 10/1
5094.112 ∅ M24 x 12/1
5094.114 ∅ M24 x 14/1
5094.115 ∅ M24 x 15/1
5094.116 ∅ M24 x 16/1
5094.118 ∅ M24 x 18/1
Synthetic tube
Code Description
5094.212 ∅ M24 x 12/2
5094.214 ∅ M24 x 14/2
5094.219 ∅ M24 x 16/1.5
5094.216 ∅ M24 x 16/2
5094.217 ∅ M24 x 17/2
5094.218 ∅ M24 x 18/2
RPE / ALU tube
Code Description
5094.314 ∅ M24 x 14/2
5094.316 ∅ M24 x 16/2
5094.326 ∅ M24 x 16/2.2
5094.318 ∅ M24 x 18/2
Steel tube for C.H.
Code Description
5094.501 M24 x 1/2"
5094.503 M24 x 3/8"
Max. tightening torque
  • Precision metal tube:
    • soft copper: 45-55 Nm
    • semi-hard copper: 60-80 Nm
    • mild steel: 60-70 Nm
  • Synthetic: 30-40 Nm
  • RPE/Alu: 20-30 Nm

Clock thermostats heating / cooling

The general characteristics in bold below are valid for the thermostats 8751.050013 - 8751.050012 - 8751.0500009
  • automatic thermostat for
    • 2-pipe: heating/cooling or auto
    • 4-pipe: heating/cooling or auto
  • ventilator speed: min./med./max. or auto
  • power supply 24 VDC
  • output control 0-10 VDC
  • 1 clock thermostat per room
  • 3 programmable zones: 5+1+1
  • LCD display with background lighting
  • protection category IP30
Jaga clock thermostat
for wall mounting
Optie Jaga thermostaat voor wandopbouw Optie Jaga thermostaat voor wandopbouw maattekening

  • 2 potiential-free contacts heating/cooling (f.e. 24 VDC of 230 VAC)
  • with key card contact / window contact
  • can be mounted on a junction box with screw holes at 6 cm

CODE 
8751.050013 wall mounted
Jaga clock thermostat
for recessed/panel mounting
Optie Jaga thermostaat voor wandinbouw Optie Jaga thermostaat voor wandinbouw maattekening

  • control valves 24 VDC heating/cooling
  • thermostat to be mounted in a junction box
    • spacing holes at 6 cm
    • minimum depth 4.5 cm
    • inner dimension 5 x 5 cm or Ø 6 cm

CODE 
8751.050012 recessed/panel mounted
Siemens clock thermostat
for wall mounting
Optie Siemens thermostaat voor wandopbouw Optie Siemens thermostaat voor wandopbouw maattekening

  • unlimited adjustment possibilities: 74 features and diagnostic test
for more information: contact Jaga.

CODE 
8751.050009 wall mounted

Pre-assembled Jaga Dynamic Product Controller (JDPC)

Jaga Dynamic Product Controller increases the functionalities on Jaga products. JDPC is offered optional to all 24VDC powered dynamic Jaga products that require a 0-10V fan control signal.
The controller is factory installed and preprogrammed.

JDPC is available in different configurations such as:

  • Water temperature sensor on the coil for on/off fan control.
  • Return air and water temperature sensor for automatic changeover between heating and cooling.
  • Push button for speed control, up to 3 variable speed settings for heating and cooling.
JDPC controller zonder bedieningspaneel
Without control panel

  • for 2 pipe model for building-in
  • control without operation and with sensors for water and room temperature, pre-configured and assembled by Jaga
  • power supply 24 VDC
  • auto switch heating / cooling / standby
  • 1 fan speed heating
    (starts at water t° >28°C, easily adjustable)
  • 1 fan speed cooling
    (starts at water t° <18°C, easily adjustable)
  • 0-10 V input for building management system/thermostat
    (contact Jaga for more information)

CODE 
DPC.BRC3 Heating and cooling

Power supply DIN-rail montage

Voeding DIN-rail montage Voeding DIN-rail montage - maattekening

The guarantee is only valid if the original Jaga power supply is used.

CODEHLDOutput
Watt
Output current
A
7990.054 9.0 3.5 5.9 36 1.5
7990.055 9.0 5.3 5.9 60 2.5
7990.056 9.0 7.0 5.9 92 3.9
7990.053 12.5 12.6 8.3 240 10
Required power = sum of the power consumption of the devices
  • for DIN-rail- or wall mounting
  • conformity: UL60950 / UL508 / IEC 60950-1 / TUV EN61558-2-16 / Class 2
  • output voltage 24 VDC
  • input voltage 100 - 240 VAC
  • screw connection
  • LED indicator
Maximum cable length

Maximum cable length in function of the number of devices. See manual.

Pre-mounted power supply

Losse voeding
  • with waterproof cable gland
  • conformity: UL1310 - EN 60950-1 / Class 2
  • output voltage 24 VDC
  • input voltage 100 - 240 VAC
  • dimension L 14.5 x B 4.5 x H 3.0 cm

CODE Output
Watt
Output current
A
/P 30 1.25
Add /P to the code of Briza.
Example: BZMW.041 072.XXX/20/P

Jaga two-way valve and thermoelectric drive 230V

Tweewegventiel en thermo-elektrische motor 230 volt
  • only for mounting on the distributor, not on the device!
  • with caristor to protect against power surge
  • with position indicator (open/closed)
  • sleeve coupling 1/2" to be provided by the installer
CODE Description
7990.409 180° - G1/2"F / NG 230V 2Watt
7990.411 180° - G3/4"F / NG 230V 2Watt
Sleeve couplings 1/2"
PRECISION METAL TUBE
Code Description
5098.110 ∅ 1/2" x 10/1
5098.112 ∅ 1/2" x 12/1
5098.114 ∅ 1/2" x 14/1
5098.115 ∅ 1/2" x 15/1
5098.116 ∅ 1/2" x 16/1
5098.118 ∅ 1/2" x 18/1
SYNTHETIC TUBE
Code Description
5098.212 ∅ 1/2" x 12/2
5098.214 ∅ 1/2" x 14/2
5098.219 ∅ 1/2" x 16/1.5
5098.216 ∅ 1/2" x 16/2
5098.217 ∅ 1/2" x 17/2
5098.218 ∅ 1/2" x 18/2
RPE / ALU TUBE
Code Description
5098.314 ∅ 1/2" x 14/2
5098.316 ∅ 1/2" x 16/2
5098.326 ∅ 1/2" x 16/2.2
5098.318 ∅ 1/2" x 18/2
STEEL TUBE FOR C.H.
Code Description
5094.501 ∅ 1/2" x 1/2"
5094.503 ∅ 1/2" x 3/8"
Max. tightening torque
  • Precision metal tube:
    • soft copper: 45-55 Nm
    • semi-hard copper: 60-80 Nm
    • mild steel: 60-70 Nm
  • Synthetic: 30-40 Nm
  • RPE/ALU: 20-30 Nm

Air exhausting grille

90°Air outlet corner piece with exhaust grille
Briza voorzetrooster
Controle range 3 cm
CODE For Briza L
5927.00005201 052
5927.00007201 072
5927.00010201 102
5927.00012201 122
uitblaaskap >3 cm
Controle range 6 cm
CODE For Briza L
5927.00005202 052
5927.00007202 072
5927.00010202 102
5927.00012202 122
uitblaaskap >6 cm

* Minimum dimensions air outlet (without optional exhaust grille)
Air outlet grille
Briza voorzetrooster
CODE For Briza L
5627.00010001 052
5627.00010002 072
5627.00010003 102
5627.00010004 122

 

Manual

Manual Briza Ceiling model
Manual Briza

Technical information

Product description Briza Ceiling model